Connect Errors

Connect Errors - the most common connection errors occur due to faulty or intemittent connections. If you receive a "Error connecting to TCF" error, check the following possible problem sources.

- Check the COM port assignment of your USB-to-Serial converter as described under Determining COM Port.
- Check that the PC Serial Port connector, if not purchased from Optec, is wired correctly.
- Check the flat Reverse cable. You easily check that each end of the RJ12 connectors are wired straight through. That is, Pin 1 on one connector should be connected to Pin 1 on the opposite connector. When looking at the Reverse cable connector ends, the wire colors should appear identical as shown below.

- Check that the RJ12 connectors are properly inserted into the TCF-S focuser control box and the PC Serial Port Converter.
Copyright � 2009, 2010 - Optec, Inc. - 199 Smith Street - Lowell, MI 49331 - U.S.A.