The TCFparms.txt text file holds some the operating variables and is located in the program directory (i.e. C:\Program Files\Optec\TCF Control\1.30\tcf). These values can be changed by using TCF-S Control as described on the previous pages or by using a simple text editor such as Notepad.exe. However, entering non-printable ASCII values or mixing up the order of the variables could cause the program to crash. Thus, it is suggested that these variables be changed only within TCF-S Control.
The following list the default values and their proper order:
0 |
com port number |
The zero value instructs the TCF-S control program to ask for your COM port number before proceeding. Otherwise, this value will be the number of the COM port set in Setup-Select COM Port; default is 0. |
0 |
display steps in the DRO |
Change to 1 to display millimeters in the DRO; default is 0. |
0 |
flag for enabling or disabling use of temperature probe |
0 = enabled, 1= disabled; default is 0. |
1 |
flag for determining focuser model type |
1 = TCF-S, 3 = TCF-S3; default is 1. |